描述
General
Controller
- CPU ARM926 200 MHz 32 Bit
- 4 MB flash program memory
- 4 kB FRAM memory for retain data
- 32 MB SD RAM
- 2 MB flash memory for diagnostic
- SD memory slot
- Real-time clock (RTC)
- Watchdog for system monitoring
- start-up time: approx. 15 s
Software
- Realtime operating system rcX
- Soft-PLC KW Software ProConOS®
- Programming languages as per IEC 61131-3: FBD, LD, ST, IL, SFC
- Flexible fieldbus configuration
- Visualization per OPC
Bus interface
Bus system
FB1: MVB ESD+, Class 1.3
Connection type, incoming bus
X2: SUB-D socket connector, 9-pin, M3 thread
Connection type, continuing bus
X3: SUB-D plug connector, 9-pin, M3 thread
Configuration
The field bus is configured by software.
Connection type, incoming bus
X4: SUB-D socket connector, 9-pin, M3 thread
Connection type, continuing bus
X5: SUB-D plug connector, 9-pin, M3 thread
Configuration
The field bus is configured by software.
Bus system
L-Bus Interface for local I/O modules
max. number of connectable slaves: 10
Bus system
TCP/IP/UDP or OPC
Connection
- X6: 4-pin M12 connector D-coded
- programming and debugging interface
Bus system
Serial Interface RS232
Connection
X7: SUB-D plug connector, 9-pin, M3 thread
Supply module electronic
Voltage range, incl. ripple
DC 16.8 – 30 V
Rated current (at UN)
- 200 mA + current consumption of connected L-Bus modules
- 2 A fusible link, in case of internal short circuit
- 1.25 A fusible link, in case of short-circuit of local-bus interface
Current consumption via local bus
max. 1 A
Connection
- X1: Terminal 5-pin
- Spring terminal: 0.14 – 2.5 mm2, AWG 22 – 12
- Stripping length: 11 mm
- Screwdriver: 3.5 × 0.6 mm
Diagnostics
Diagnosis indications
- Device status (PLC) LED yellow
- Function freely programmable (APP) LED red/green
- MVB status (FB1ST) LED green
- MVB status (FB1ST) LED green
- CANopen status (FB2ST) LED green
- CANopen error (FB2ERR) LED red
- L-Bus status (LB) LED red/green
- Logic supply(UL) LED green
- Ethernet Link (LNK) LED green
- Ethernet Activity (ACT) LED yellow
- Push-button (J1USER) function programmable
- Push-button (J2RESET) for warm start
Electrical isolation
Isolating voltage
- AC 500 V Ethernet and elektronics
- AC 500 V MVB and electronics
- AC 500 V CAN and electronics
Technical data
Mounting
DIN rail mounting
Installation postition
- As desired
- Installation space:
- top: 5 mm (for assembly)
- bottom: 5 mm (for assembly)
- side: 0 mm
Dimensions (w × h × d)
123×141,5×64,1 mm
Operating temperature
-40 °C … +70 °C
Storage temperature range
-40°C…85°C
PE connection
Connection tab
X0: 6.3 mm × 0.8 mm
Standards
EN 45545-2: Railway applications – Fire protection on railway vehicles – Part 2: Requirements for fire behaviour of materials and components
Failure Rate Prediction (MTBF)
Standards
- Electronic components – Reliability – Reference conditions for failure rates and stress models for conversion: EN/IEC 61709
- Failure Rates of Components – Expected values: SN 29500
Failure rate at +45 °C
2430 fit
Failure rate at +45 °C
411512 h
1 fit equals one failure per 109 component hours
The indicated temperature is the mean component ambient temperature.
Comments
- The results are valid under following conditions:
- Automotive environment or industrial areas without extreme dust levels and harmful substances
- Continuous operation 8760 h per year
Accessories
- Not included in the delivery:
- SUB-D refitting set M3 in UNC4/40, part number 746840
- Included in the delivery:
- Screwless terminal, power supply, part number 745861
- “Lütze MVB Configurator” version 1.0