Technical data
Voltage range
DC 50.4 V – 137.5 V
Output voltage
DC 24 V ± 10 %
Protection device
- Polarity reversal protection
- Suppressor diode
Status indication LED
Yellow LED
Protection device output
- Short-circuit protection
- Overload protection
- Internal overtemperature protection with automatic restart
Relay
Control voltage US
DC 24 V ±10 %
Output voltage
min. DC 17 V / max. DC 250 V
Output current
min. 5 mA / max. 200 mA
Protection device Input
Varistor
Clearance/creepage dist.
(control/load side)
>5.5 mm
Safe isolation
between control and load sides: yes
Contact type
change over contact
General
Connection type
- Push-In
- single-wire 0.20 – 2.5 mm2
- AWG 20 – AWG 14
- fine stranded 0.20 – 2.5 mm2
- AWG 20 – AWG 12
- Stripping length: 8 mm
- Screwdriver: 3.5 × 0.6 mm
Operation temperature range
-40°C…70°C
Storage temperature range
-40°C…85°C
Dimensions (w × h × d)
22,5×79×84 mm
Mounting
- DIN rail mountable TS35
- (EN 60715)
Installation postition
As desired
Form
22.5 mm Microcompact
Standards
- EN 50155:2007-07: Railway applications – Rolling stock – Electronic equipment
- EN 50121-3-2:2016-12: Railway applications – Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus
- EN 50124-1:2017-03: Railway applications – Insulation coordination – Part 1: Basic requirements – Clearances and creepage distances for all electrical and electronic equipment
- EN 61373:2010-09: Railway applications – Rolling stock equipment – Shock and vibration tests
- EN 45545-2:2013+A1:2015: Railway applications – Fire protection on railway vehicles – Part 2: Requirements for fire behaviour of materials and components
Failure Rate Prediction (MTBF)
Standards
- Electronic components – Reliability – Reference conditions for failure rates and stress models for conversion: EN/IEC 61709
- Failure Rates of Components – Expected values: SN 29500
Failure rate at +45 °C
129 fit
Failure rate at +45 °C
7734371 h
1 fit equals one failure per 109 component hours
The indicated temperature is the mean component ambient temperature.
Comments
- The results are valid under following conditions:
- Automotive environment or industrial areas without extreme dust levels and harmful substances
- Continuous operation 8760 h per year