Ethernet
Connection
- 8×M12 female, D coded, 4-pin
- Recommended tightening torque for protection class IP54: 0,6 Nm
Connecting lead
0 – 100 m STP
Properties
Autonegotiation
Autocrossing
Autopolarity
Twisted Pair (TP)
IEEE802.3 (CSMA / CD)
IEEE802.3u (Fast Ethernet)
IEEE802.3 (Full Duplex Flow Control)
Store and Forward Switching Mode
Network topology
Line/Star/Ring
Data rate
10 / 100 Mbit/s per port
Input (digital)
Number
1 digital input, Type 3 acc. to EN 61131-2
Relay
Number
1 configurable contact (NO or NC)
Output voltage
AC/DC 150 V
Load
- DC 2 A @ DC 30 V
- DC 0.4 A @ DC 150 V
USB
Current Consumption
max. 100 mA
Management Features
Diagnosis
cyclic system port monitoring, port status, configuration check, port mirroring, packet capture, SNMP Traps
Ring Protocol
Rapid Spanning Tree
Management Service & Filter
- Quality of Service (QoS)
- Port trunking
- Link Aggregation
- Broadcast Storm Protection
- Port based VLAN
- Port disabling
- NTP
- LLDP
Voltage range
Voltage range
DC 24 … 110 V
Connection
- M12 male A coded, 4-pin
- Recommended tightening torque for protection class IP54: 0,6 Nm
Current Consumption
- bei 2 Teilnehmern
- 24 V / 150 mA
- 72 V / 60 mA
- 110 V / 40 mA
- bei max. Portbelegung
- 24 V / 260 mA
- 72 V / 100 mA
- 110 V / 70 mA
Diagnostics
Diagnosis indications
- Logic supply(UL) LED green
- Link & Activity (LNK/ACT) LED yellow
- 10/100M Speed, LED green
- Digital Input (DI), LED yellow
- Relay Output (RO), LED yellow
- Status (Status), LED green and red
Connection
- M12 A-coded female, 8-pin
- Recommended tightening torque for protection class IP54: 0,6 Nm
Configuration
- via Webserver
- via USB2.0 Flash drive
Electrical isolation
Isolating voltage
- AC 1500 V all potentials against PE/Power/Ethernet/relay contact
- AC 1000 V digital input against USB
Technical data
Dimensions (w × h × d)
158×144×37 mm
Operating temperature
-40 °C … +70 °C (+85 °C for 10 min)
Storage temperature range
-40°C…85°C
Relative air humidity
10 – 90 %, non-condensing
Application height
0 – 2000 m
Standards
- EN 50155:2007-07: Railway applications – Rolling stock – Electronic equipment
- EN 50121-3-2:2016-12: Railway applications – Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus
- EN 50124-1:2017-03: Railway applications – Insulation coordination – Part 1: Basic requirements – Clearances and creepage distances for all electrical and electronic equipment
- EN 61373:2010-09: Railway applications – Rolling stock equipment – Shock and vibration tests
- EN 45545-2+A1:2015-10: Railway applications – Fire protection on railway vehicles – Part 2: Requirements for fire behaviour of materials and components
- HN_Isolationsprüfung:2017-03: Company internal standard – Insulation test
PE connection
Screw terminal
- M4, hexagon socket, widths across flats 3
- Recommended tightening torque 2 Nm
Failure Rate Prediction (MTBF)
Standards
- Electronic components – Reliability – Reference conditions for failure rates and stress models for conversion: EN/IEC 61709
- Failure Rates of Components – Expected values: SN 29500
Failure rate at +45 °C
2346 fit
Failure rate at +45 °C
426223 h
1 fit equals one failure per 109 component hours
The indicated temperature is the mean component ambient temperature.
Comments
- The results are valid under following conditions:
- Automotive environment or industrial areas without extreme dust levels and harmful substances
Accessories
- Included in the delivery:
- M12 locking screws for blank ports
- Recommended tightening torque for protection class IP54: 0,4 Nm
- Not included in the delivery:
- DIN rail mounting set, part number 804210
- USB adapter line, part number 804211 (without protection class IP54 – for configuratoin without Webserver)