Technical data
Connection method
Diodes can be individually activated
Rated voltage UN
max. AC/DC 440 V
Rated current (at UN)
0.5 A
Blocking-state current
50 µA
Conducting-state voltage
0.9 – 1.3 V
Diode
EM513 (DC 1 A / 1600 V)
Diode blocking voltage
1600 V
General
Form
6.2 mm Microcompact, 6-pin
Mounting
- DIN rail mountable TS35
- (EN 60715)
Connection type
- Spring terminal: single stranded 0.08 – 2.5 mm2, fine stranded 0.08 – 2.5 mm2
- Stripping length: 10 mm
- Screwdriver: 3.5 × 0.6 mm
Rated insulation voltage
AC/DC 300 V (functional insulation)
Over voltage category
OV2
Operation temperature range
-40 °C … +70 °C (+85 °C 10 min)
Storage temperature range
-40°C…85°C
Dimensions (w × h × d)
6,2×90×92,5 mm
Standards
- EN 50155:2007-07: Railway applications – Rolling stock – Electronic equipment
- EN 50124-1:2001-03: Railway applications – Insulation coordination – Part 1: Basic requirements – Clearances and creepage distances for all electrical and electronic equipment
- EN 61373:2010-09: Railway applications – Rolling stock equipment – Shock and vibration tests
- EN 45545-2: Railway applications – Fire protection on railway vehicles – Part 2: Requirements for fire behaviour of materials and components
Failure Rate Prediction (MTBF)
Standards
- Electronic components – Reliability – Reference conditions for failure rates and stress models for conversion: EN/IEC 61709
- Failure Rates of Components – Expected values: SN 29500
Failure rate at -40 °C
4 fit
Failure rate at +45 °C
10 fit
Failure rate at +70 °C
21 fit
1 fit equals one failure per 109 component hours
The indicated temperature is the mean component ambient temperature.
Comments
- The results are valid under following conditions:
- Automotive environment or industrial areas without extreme dust levels and harmful substances